{"id":1258,"date":"2022-03-29T15:15:16","date_gmt":"2022-03-29T20:15:16","guid":{"rendered":"https:\/\/shearanything.com\/?p=1258"},"modified":"2022-05-17T06:24:58","modified_gmt":"2022-05-17T11:24:58","slug":"optimized-well-design-enabled-by-an-improved-well-control-barrier-the-shear-anything-k-bos","status":"publish","type":"post","link":"https:\/\/dev.ravendigit.al\/shearanything\/board\/optimized-well-design-enabled-by-an-improved-well-control-barrier-the-shear-anything-k-bos\/","title":{"rendered":"Optimized Well Design Enabled by an Improved Well Control Barrier: the \u00e2\u20ac\u0153Shear Anything\u00e2\u20ac\u009d K-BOS"},"content":{"rendered":"<p>The K-BOS provides the ability to shear anything which enables drilling engineers to consider optimizations to a well design \/ completion or intervention. Opportunities such as landing a longer and heavier production casing into the hydrocarbon zone or even removing a casing string, may have been previously unacceptable due to unshearable exposure. Considering drilling systems with limited shearing capability like the 13-5\/8&#8243; 10,000 psi BOPs typical in surface drilling rigs, there are many fields where the K-BOS enables a revision of design limitations based on unshearable exposure resulting in cost reductions and enhancements to the production profile of a given reservoir.<\/p>\n<p><strong><span style=\"text-decoration: underline;\">Improved shear\/seal capability and WC barrier enables:<\/span><\/strong><\/p>\n<ul>\n<li>Larger\/thicker-wall casing \/ production strings<\/li>\n<li>Completion components\n<ul>\n<li>Tubing + control lines; gravel pack equipment<\/li>\n<li>Potential enabler for single trip completions<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p><span style=\"text-decoration: underline;\"><strong>Value: Improved well productivity<\/strong><\/span><\/p>\n<ul>\n<li>Larger production casing<\/li>\n<li>Larger tubing (especially in HPHT wells)<\/li>\n<li>Simplify control system for MUX SSTT<\/li>\n<\/ul>\n<p><strong>13-5\/8&#8243; 10,000 psi K-BOS examples:<\/strong><\/p>\n<p><img loading=\"lazy\" class=\"size-large wp-image-1216 alignnone\" src=\"https:\/\/dev.ravendigit.al\/shearanything\/wp-content\/uploads\/2022\/03\/13-10M-K-BOS-Shear-Anything-Picture-1024x859.jpg\" alt=\"\" width=\"1024\" height=\"859\" srcset=\"https:\/\/dev.ravendigit.al\/shearanything\/wp-content\/uploads\/2022\/03\/13-10M-K-BOS-Shear-Anything-Picture-1024x859.jpg 1024w, https:\/\/dev.ravendigit.al\/shearanything\/wp-content\/uploads\/2022\/03\/13-10M-K-BOS-Shear-Anything-Picture-300x252.jpg 300w, https:\/\/dev.ravendigit.al\/shearanything\/wp-content\/uploads\/2022\/03\/13-10M-K-BOS-Shear-Anything-Picture-1536x1288.jpg 1536w, https:\/\/dev.ravendigit.al\/shearanything\/wp-content\/uploads\/2022\/03\/13-10M-K-BOS-Shear-Anything-Picture-250x210.jpg 250w, https:\/\/dev.ravendigit.al\/shearanything\/wp-content\/uploads\/2022\/03\/13-10M-K-BOS-Shear-Anything-Picture.jpg 1574w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/p>\n<p><em>Shown above: Shear test result using the 13-5\/8&#8243; 10,000 psi K-BOS<\/em><\/p>\n<p><strong>18-3\/4&#8243; 15,000 psi K-BOS examples:<\/strong><\/p>\n<p><img loading=\"lazy\" class=\"size-full wp-image-1229 alignnone\" src=\"https:\/\/dev.ravendigit.al\/shearanything\/wp-content\/uploads\/2022\/03\/Shearing-Prediction-vs-Result.jpg\" alt=\"\" width=\"708\" height=\"366\" srcset=\"https:\/\/dev.ravendigit.al\/shearanything\/wp-content\/uploads\/2022\/03\/Shearing-Prediction-vs-Result.jpg 708w, https:\/\/dev.ravendigit.al\/shearanything\/wp-content\/uploads\/2022\/03\/Shearing-Prediction-vs-Result-300x155.jpg 300w, https:\/\/dev.ravendigit.al\/shearanything\/wp-content\/uploads\/2022\/03\/Shearing-Prediction-vs-Result-250x129.jpg 250w\" sizes=\"(max-width: 708px) 100vw, 708px\" \/><\/p>\n<p><em>Shown above: A predictive model of shearing performance (left) of the 18-3\/4&#8243; 15,000 psi K-BOS is compared to the results of a shear test (right) using a 16-1\/4&#8243; OD 136# Q125 casing.<\/em><\/p>\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" class=\"size-large wp-image-1228 alignnone\" src=\"https:\/\/dev.ravendigit.al\/shearanything\/wp-content\/uploads\/2022\/03\/shearing-capability-analysis-1024x569.jpg\" alt=\"\" width=\"1024\" height=\"569\" srcset=\"https:\/\/dev.ravendigit.al\/shearanything\/wp-content\/uploads\/2022\/03\/shearing-capability-analysis-1024x569.jpg 1024w, https:\/\/dev.ravendigit.al\/shearanything\/wp-content\/uploads\/2022\/03\/shearing-capability-analysis-300x167.jpg 300w, https:\/\/dev.ravendigit.al\/shearanything\/wp-content\/uploads\/2022\/03\/shearing-capability-analysis-250x139.jpg 250w, https:\/\/dev.ravendigit.al\/shearanything\/wp-content\/uploads\/2022\/03\/shearing-capability-analysis.jpg 1220w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/p>\n<p><em>Shown above: The Kinetic Energy margin of Safety for the 18-3\/4&#8243; 15,000 psi K-BOS is shown for a broad set of heavy casings. Notable shearable tubulars include the 10-3\/4&#8243; 109# SDSS125.<\/em><\/p>\n<p><img loading=\"lazy\" class=\"size-large wp-image-1234 alignnone\" src=\"https:\/\/dev.ravendigit.al\/shearanything\/wp-content\/uploads\/2022\/03\/well-productivity-chart-1024x657.jpg\" alt=\"\" width=\"1024\" height=\"657\" srcset=\"https:\/\/dev.ravendigit.al\/shearanything\/wp-content\/uploads\/2022\/03\/well-productivity-chart-1024x657.jpg 1024w, https:\/\/dev.ravendigit.al\/shearanything\/wp-content\/uploads\/2022\/03\/well-productivity-chart-300x193.jpg 300w, https:\/\/dev.ravendigit.al\/shearanything\/wp-content\/uploads\/2022\/03\/well-productivity-chart-250x160.jpg 250w, https:\/\/dev.ravendigit.al\/shearanything\/wp-content\/uploads\/2022\/03\/well-productivity-chart.jpg 1530w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/p>\n<p><em>Shown above: The chart illustrates the relative increase in production achieved by increasing the internal diameter of a given well&#8217;s production tubing resulting in improved economics for an entire project.<\/em><\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The K-BOS provides the ability to shear anything which enables drilling engineers to consider optimizations to a well design \/ completion or intervention. Opportunities such as landing a longer and heavier production casing into the hydrocarbon zone or even removing a casing string, may have been previously unacceptable due to unshearable exposure. Considering drilling systems [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[1,12],"tags":[],"_links":{"self":[{"href":"https:\/\/dev.ravendigit.al\/shearanything\/wp-json\/wp\/v2\/posts\/1258"}],"collection":[{"href":"https:\/\/dev.ravendigit.al\/shearanything\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dev.ravendigit.al\/shearanything\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dev.ravendigit.al\/shearanything\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/dev.ravendigit.al\/shearanything\/wp-json\/wp\/v2\/comments?post=1258"}],"version-history":[{"count":13,"href":"https:\/\/dev.ravendigit.al\/shearanything\/wp-json\/wp\/v2\/posts\/1258\/revisions"}],"predecessor-version":[{"id":1322,"href":"https:\/\/dev.ravendigit.al\/shearanything\/wp-json\/wp\/v2\/posts\/1258\/revisions\/1322"}],"wp:attachment":[{"href":"https:\/\/dev.ravendigit.al\/shearanything\/wp-json\/wp\/v2\/media?parent=1258"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dev.ravendigit.al\/shearanything\/wp-json\/wp\/v2\/categories?post=1258"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dev.ravendigit.al\/shearanything\/wp-json\/wp\/v2\/tags?post=1258"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}